Aller au contenu
Université Echahid Hamma Lakhdar d’El OuedPortail de la recherche
Article

PumpSpectra: An MCSA-Based Platform for Fault Detection in Centrifugal Pump Systems

Résumé

Reliable detection of faults in centrifugal pump systems is challenging in industrial environments due to harsh operating conditions, limited sensor access, and the need for fast, explainable decisions. We developed PumpSpectra, an industrial Motor Current Signature Analysis (MCSA) platform that processes uploaded stator-current CSV files using FFT/STFT with transparent, rule-based models designed to identify mechanical faults including misalignment, bearing defects, and impeller anomalies; field validation demonstrated misalignment detection. In a case study at the El Oued desalination plant (Algeria; n=40 operating points), PumpSpectra achieved 91.2% diagnostic accuracy with a 95% reduction in analysis time compared to manual MCSA post-processing, and a false-positive rate of 3.8% at 0.1 Hz resolution. These results suggest that current-only, explainable analytics can support predictive maintenance programs by accelerating fault triage, improving traceability of decisions, and reducing avoided maintenance costs in pump-driven industrial assets.

Détails

Langue originaleEnglish
RevueSensors
Volume25
Numéro22
Pages6916
ÉditeurMultidisciplinary Digital Publishing Institute
ISSN1424-8220
DOI10.3390/s25226916
Statut de publicationPublié — 12 novembre 2025

Mots-clés

Objectifs de développement durable

  • 9 — Industrie, innovation et infrastructure

Empreinte